saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Blower Motor Switch|Installation|Page 8156 > < Blower Motor Switch|Testing and Inspection
Page 1
background image

Blower Motor Switch: Service and Repair
Installation

NOTE:  On initiating calibration, all previous trouble codes will be cleared. Before starting calibration, a readout must be obtained of all trouble codes
stored in the memory.

1. Plug in the connector.
2. Smear a thin coating of silicon paste, part No. (45) 30 07 895, on the surface of the fan control unit in contact with the evaporator.
3. Install the fan control unit in place and tighten the screws. Start the ventilation fan and run it at maximum speed. Check that condensate does not

leak out of the evaporator. Improve the sealing as necessary.

4. Refit the protective cover.
5. Refit the floor air duct.
6. Refit the panel on the side of the centre console.
7. Refit the glove box.
8. Calibrate the ACC system by pressing the "AUTO" and "OFF" buttons simultaneously.

Blower Motor Switch|Installation|Page 8156 > < Blower Motor Switch|Testing and Inspection