saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

04950569 > < Ventilation Fan - Inoperative|Page 8243
Page 3
background image

Showa evaporator

On Showa evaporators, the cooling plate on which the fan control is mounted is screwed to the evaporator.

Important

The aluminium spacer supplied with the fan control unit is not to be used.

Wipe away old silicon paste from the mounting surface on the evaporator.

Apply a thin coat of silicon paste, part no. 30 07 895 on the metal plate on the fan control unit and the screwed plate on the evaporator. This is
important for the function and service life.

Make sure the two sleeves on the fan control unit fit into the holes in the mounting surface of the evaporator. Screw the fan control unit to the evaporator.
Plug in the connector.

Check the fitting and replace all removed parts, see "8. Climate control, Adjustment/replacement, Fan control unit".

Warranty/Time information

Failed Object: 87076
Fault/Reason code: 71
Location code: 01
Warranty Type (US): 01
Repair/Action code: 01
Labour Operation (US): 87076
(Labor Op. CA: D0540 0.2 hrs.)
Time: 0.2

04950569 > < Ventilation Fan - Inoperative|Page 8243