Robinair 17644 Draining Equipment And Robinair 10094 Vacuum Pump - Draining

1. Open the red cock ("Gas") for gaseous refrigerant on the draining station's container.
2. Connect the yellow hose on the pressure gauge stand's middle outlet to the inlet side of the draining station.
3. Using a snap-on coupling, connect the blue low-pressure hose to the low-pressure side of the A/C system.
4. Using a snap-on coupling, connect the red high-pressure hose to the high-pressure side of the A/C system.
5. Open the valves on both snap-on couplings by screwing in the knobs.

6. Open the cocks on the blue low-pressure hose and red high-pressure hose on the pressure-gauge stand.
7. Start the draining station.
8. If the draining station operates correctly, it should show negative pressure when the draining valve is closed.
9 Open the draining valve and drain the A/C system of refrigerant.

10. Close the draining valve when the gauge on the draining station shows negative pressure (about 10 inch Hg).
11. Turn off the draining station.