4

Unplug the radiator fan connector and check that:

1-speed fan
-

12 V power supply is present between pin 1 and a good grounding point.

-

resistance between pin 2 and a good grounding point is less than 1 ohm.

Also check that:
2-speed fan
-

12 V power supply is present between pin 1 of the connector and a good grounding point.

5

If it is not, check the leads for continuity/shorting, as follows:
-

between pin 87 of the relay holder connector and pin 1 of the 1-speed radiator fan connector.

-

between pin 87 of the relay holder connector and pin 1 of the 2-speed radiator fan connector.

6

If the radiator fan still does not work in spite of the above checks, change the radiator fan motor.