900 SE Hatchback L4-1985cc 2.0L DOHC Turbo EFI (1997)
Manifold Pressure/Vacuum Sensor: Specifications
Voltage Output
Voltage Output
Voltage/Pressure
Note: Pressure in kPa is absolute pressure, i.e. 100 kPa
corresponds to barometric pressure. When checking the
pressure sensor using a pressure- vacuum pump, somewhat
lower voltage readings may be obtained at higher
altitudes.
0.48 V at 25 kPa
Note: Approximate voltage. Power supply 5 V.
0.95 V at 50 kPa
Note: Power supply 5 V.
1.9 V at 100 kPa
Note: Power supply 5 V.
2.4 V at 125 kPa
Note: Power supply 5 V.
2.8 V at 150 kPa
Note: Power supply 5 V.
3.3 V at 175 kPa
Note: Power supply 5 V.