Tightening torque 55 Nm (41 lbf ft).

4

Make sure the oxygen sensor cable is not twisted and position the lower cable clamp over the adhesive tape on the oxygen sensor cable. The
bottom edge of the tape must correspond with the bottom edge of the cable clamp. Position the cable clamp so that the oxygen sensor cable
follows an even line with a slight bend between the clamp and the oxygen sensor. Tighten the screw on the cable clamp.

Tightening torque 20 Nm (15 lbf ft)

5

Lower the car, lay the cable as shown in the illustration and tighten the upper cable clamp.

Tightening torque 6 Nm (4.5 lbf ft).

6

Fasten the cable to the coolant pipe with two clamps and connect the cable.

Important

It Is important that the connector is plugged in correctly and secured.

Warranty/Time Information

To resolve a customer complaint for a vehicle in warranty, submit a claim using the following information:

Failed object: 25441

Fault/Reason code: 17

Location code: 9

Warranty Type (US): 01

Repair/Action code: 01

Labour Operation (US): 25441

Time: 0.3

(CA: J6372 0.3 hrs.)