saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Menu Structure For Command Codes|Page 2841 > < Menu Structure For Command Codes|Page 2839
Page 1
background image

Maintenance Required Lamp/Indicator: Adjustments

Starting with M 1995, the Intelligent Saab Tester (ISAT) scan tool is equipped for programming Saab Information Display (SID) 2/3 and SID 4 (SID 1
with audio display). Basic programming is carried out
Only once. The ISAT scan tool with PROM 7.01 shows how the instrument is programmed and the routine can then be used to check existing
instruments. Basic setting is carried out for the following functions, which must be adapted to the relevant market by means of the adjustment commands.

-

Service Indication 
The normal service interval is 20,000 km. This can be programmed and changed with "SERVICE INDICATOR" in the menu headed
"ADJUSTMENT".

-

Language
The basic setting (English) can be changed with "CHOOSE LANGUAGE" in the menu headed "ADJUSTMENT".".

-

Unit of measurement
The basic setting (metric) can be changed by means of the SID unit's push-button.

-

Speed warning ME
This function is not active in the basic setting. It is activated with "SPEED WARNING ME" in the menu headed "ADJUSTMENT".".

Important:  Before programming is started, it is advisable to note the SID version and current equipment (Sensonic, TSAS or normal). These details are
needed in connection with programming.

ISAT SCAN TOOL DISPLAY 1

SAAB INFO DISPLAY 

ADJUSTMENT

=>PROGRAMMING 

READ SYSTEM INFO

1

Select PROGRAMMING in the ISAT scan tool's SAAB INFO DISPLAY program.

ISAT SCAN TOOL DISPLAY 2

PROGRAMMING A 
NEW SID UNIT
F1 = CONTINUE
ESC = END

2

Proceed to the programming phase or end.

ISAT SCAN TOOL DISPLAY 3

SELECT TYPE OF 
SID UNIT

SID 2/3

SELECT

3

Specify the SID type, either SID 2/3 or SID 4 (SID 4 = SID 1 with audio display).

ISAT SCAN TOOL DISPLAY 4

SELECT EQUIPMENT

XXX

SELECT

4

Specify the equipment, either ACS (Sensonic) HOOD (TSAS), ACS/HOOD or NORMAL

ISAT SCAN TOOL DISPLAY 5

PROGRAMMING WILL 

NOW OCCUR
F1 = OK
ESC = END

5

Program the instrument with the entered details.

Important: Both commands will result in programming of the instrument. This will be corrected for M 1996.

SAT SCAN TOOL DISPLAY 6

Menu Structure For Command Codes|Page 2841 > < Menu Structure For Command Codes|Page 2839