Manifold Absolute Pressure Sensor: Specifications

VOLTAGE AT:  

25 kPa (-0.75 bar):  Approx. 0.48 V
50 kPa (-0.50 bar):  Approx. 0.95 V
100 kPa (±0 bar):  Approx. 1.9 V
125 kPa (0.25 bar):  Approx. 2.4 V
150 kPa (0.50 bar):  Approx. 2.8 V
175 kPa (0.75 bar):  Approx. 3.3 V

Pressures stated refer to absolute pressure, i.e. 100 kPa corresponds to atmospheric pressure. 

When checking the pressure sensor with a pressure-vacuum pump, lower voltages may be obtained when measuring at high altitude.

5 V voltage supply.