Housing Assembly HVAC: Service and Repair
Blower Case Replacement

Blower Case Replacement

Removal Procedure

1. Remove the air inlet screen. Refer to Air Inlet Screen Replacement   (See: Air Duct/Service and Repair/Air Inlet Screen Replacement).

2. Remove the recirculating air valve housing, outside. 

1. Remove the 4 bolts (1).
2. Remove the recirculating air valve housing grille (3). 
3. Remove the bolt for recirculating air valve housing (2). 