Aura L4-2.4L (2008)
Condenser HVAC: Service and Repair
Condenser Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
Important: The desiccant is inside the condenser and is not serviced separately. The condenser must be replaced if new desiccant is
required.
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging (See: Service and Repair/Procedures/Refrigerant Recovery and
Recharging).
2. Remove the left and right headlamp assemblys. Refer to Headlamp Replacement (See: Lighting and Horns/Headlamp/Service and Repair).
3. Loop a rope around each of the 2 upper tabs of the radiator and tie the rope around the upper tie bar.
4. Remove both upper radiator support bracket bolts.
5. Remove both upper radiator support brackets.