Liquid Line Replacement
Liquid Line Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging (See: Service and Repair/Procedures/Refrigerant Recovery and
Recharging).
2. Remove the refrigerant pressure sensor wire harness connector.
3. Remove the refrigerant pressure sensor.
4. Remove the liquid line bracket bolt.
5. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement (See: Engine, Cooling and Exhaust/Engine/Tune-up and Engine
Performance Checks/Air Cleaner Housing/Service and Repair).
6. Remove the surge tank from the surge tank bracket.
7. Remove the suction hose and liquid line nut from the thermal expansion valve (TXV).
8. Remove the suction hose and liquid line from the TXV.