Aura L4-2.4L (2008)
Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
Important: Refrigerant recovery is not required.
1. Remove the refrigerant pressure sensor wire harness connector.
2. Remove the refrigerant pressure sensor.
3. Remove and discard the O-ring.
Installation Procedure
1. Install a new O-ring. Refer to O-Ring Replacement (See: Coupler HVAC/A/C Coupler O-ring/Service and Repair/O-Ring Replacement).
Notice: Refer to Fastener Notice (See: Service Precautions/Vehicle Damage Warnings/Fastener Notice).
2. Install the refrigerant pressure sensor.
Tighten to 5 N.m (44 lb in).