Refrigerant Pressure Sensor / Switch: Service and Repair

Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement

Tools Required

J 39400-A Halogen Leak Detector

Removal Procedure

Important:  Refrigerant recovery is not required.

1. Remove the refrigerant pressure sensor wire harness connector. 
2. Remove the refrigerant pressure sensor.
3. Remove and discard the O-ring.

Installation Procedure

1. Install a new O-ring. Refer to O-Ring Replacement  (See: Coupler HVAC/A/C Coupler O-ring/Service and Repair/O-Ring Replacement).

Notice:  Refer to Fastener Notice  (See: Service Precautions/Vehicle Damage Warnings/Fastener Notice).

2. Install the refrigerant pressure sensor.

Tighten to 5 N.m (44 lb in).