7. Install the J 45722  to the fuel pump module lock ring.

Important:  Ensure that the lock ring is installed with the correct side facing upward. A correctly installed lock ring will only turn in a
clockwise direction.

8. Using the J 45722  and a long breaker-bar, rotate the lock ring in a clockwise direction in order the lock the lock ring.
9. Remove the J 45722  from the fuel pump module lock ring.