Aura L4-2.4L (2008)
Installation Procedure
Important: Inspect the CMP sensor for damage, replace as necessary.
1. Lubricate the CMP sensor O-ring seal with clean engine oil.
2. Install the CMP sensor.
Notice: Refer to Fastener Notice (See: Service Precautions/Vehicle Damage Warnings/Fastener Notice).
3. Install the CMP sensor bolt.
Tighten the bolt to 10 N.m (89 lb in).
4. Connect the engine wiring harness electrical connector (7) to the intake CMP sensor (6).
5. Install the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement (1st Design) (See: Fuel Delivery and Air Induction/Air Cleaner
Housing/Air Cleaner Fresh Air Duct/Hose/Service and Repair/Air Cleaner Outlet Duct Replacement (1st Design))Air Cleaner Outlet Duct
Replacement (2nd Design) (See: Fuel Delivery and Air Induction/Air Cleaner Housing/Air Cleaner Fresh Air Duct/Hose/Service and Repair/Air