Aura L4-2.4L (2008)
Alternator: Service and Repair
Generator Bracket Replacement
Removal Procedure
1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (LAT) ()Battery Negative Cable
Disconnection and Connection (LZ4/LY7) ().
2. Rotate the drive belt tensioner counterclockwise.
3. Remove the accessory drive belt. Refer to Drive Belt Replacement (See: Engine, Cooling and Exhaust/Engine/Drive Belts, Mounts, Brackets and
Accessories/Drive Belt/Service and Repair).
4. Remove the generator. Refer to Generator Replacement (LZ4) ()Generator Replacement (LY7) ().
5. Remove the drive belt tensioner bolt.
6. Remove the drive belt tensioner.
7. Remove the drive belt idler pulley bolt.
8. Remove the drive belt idler pulley.