Important:  Do not allow the upper bracket to twist when tightening the radiator mounting bolts or vibration may result.

26. Install both upper radiator support bracket bolts.

Tighten the bolt to 10 N.m (89 lb in).

27. Install the left and right headlamp assemblys.
28. Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
29. Leak test the fittings using the J 39400-A.