Coupe L4-1.9L DOHC VIN 7 (1994)
3. Inspect timing sprocket teeth on the camshaft gears, the crankshaft gear, and on the key for wear.
4. Inspect the tensioner for operation:
a. Release the plunger lock and make sure the piston moves freely.
b. Make sure the oil feed hole is open and not plugged. Submerge the tensioner in oil or solvent. Depress the plunger and observe fluid flow from
the tensioner body. Inspect the cylinder block port for blockage.
c. Measure plunger travel (chain and guides installed).
Standard: 1.16 - 9.85 mm (0.O45 - 0.388 in.).
Service Limit: 21.0 mm (0.8626 in.) max.
Installation
DOHC TIMING CHAIN, SPROCKETS, GUIDES AND TENSIONER INSTALLATION