saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Expansion Valve|Locations|Page 5745 > < Expansion Valve|Locations|Page 5743
Page 1
background image

Expansion Valve: Service and Repair

THERMAL EXPANSION VALVE (TXV)

NOTE: This article has been updated with TSB# 99-01-37-008.

REMOVAL

1. Recover refrigerant using an approved refrigerant recovery system.

CAUTION: DO NOT REMOVE HOSES OR LINES BEFORE SYSTEM IS FULLY DISCHARGED.

2. Remove air cleaner cover and air induction hose at intake manifold.

3. Remove suction hose from TXV.
4. Remove liquid line from TXV.

5. Remove TXV from evaporator.

INSTALLATION

1. Install new 0-rings on evaporator pipes. Do not lubricate O-rings. Remove protective covers from TXV.

Expansion Valve|Locations|Page 5745 > < Expansion Valve|Locations|Page 5743