Closed-Loop Criteria

^

ECT reading over 60~C (140~F).

^

Engine running at least one minute.

^

Bring engine off idle (TP sensor 7 to 10 percent) briefly to obtain closed-loop.

^

Oxygen sensor voltage should vary over 550 mV to under 350 mv

15.

Once operating temperature and closed-loop engine operation have been obtained, run for two minutes while maintaining 1500 rpm. Verify DTC
13 does not reset.

16.

If DTC 13 does reset, refer to the "Electronic Engine Controls Service Manual" for diagnostic procedures.

PARTS REQUIREMENTS:

CLAIM INFORMATION:
To receive credit for this repair during the warranty coverage period, submit a claim through the Saturn Dealer System as follows:

Customer Interest: > < O2 Sensor - MIL ON/DTC 13 Set|Page 2568