saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Front Door Panel > < Front Door Limiter|Service and Repair
Page 2
background image

Important:  The letters R and L are molded into the check link arm. If you are installing on the right side, the letter R must face up. If
you are installing on the left side, the letter L must face up.

1. Position the front door check link to the door.

Notice:  Refer to Fastener Notice  in Cautions and Notices.

2. Install the front door check link nuts.

Tighten the nuts to 10 N.m (89 lb in).

3. Install the front door check link bolt.

Tighten the bolt to 9 N.m (80 lb in).

4. Install the front door water deflector. Refer to Water Deflector Replacement - Front Door  See: Front Door Panel/Service and Repair

Front Door Panel > < Front Door Limiter|Service and Repair