INSTALLATION PROCEDURE

1. Install new seal washers to the evaporator core fittings.
2. Install the TXV.

3. Install the TXV bolts.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten
Tighten the bolts to 7 N.m (62 lb in).

4. Install new sealing washers on the condenser tube and evaporator hose fittings.
5. Install the condenser tube and evaporator hose to the TXV.
6. Install the TXV nut.