ION L4-2.4L (2007)
5. Separate the EBCM (1) from the BPMV (2) by carefully pulling apart.
Installation Procedure
1. Clean the sealing surface of the BPMV, with denatured alcohol and a clean shop cloth.
2. Install the EBCM (1) to the BPMV (2). Use care when aligning the EBCM (1) to the BPMV electrical terminals (3).
Notice: Refer to Fastener Notice.
3. Install the 4 EBCM-to-BPMV retaining bolts (1). Tighten the bolts in a criss-cross pattern.