3. With the surge tank raised, install the surge tank outlet hose.
4. Reposition the hose clamp using SA9111E to secure the hose.
Notice: Refer to Fastener Notice.
5. Install the surge tank bolt.
Tighten the bolt to 6.5 N.m (58 lb in).
6. Set the underhood junction block bracket into position.
7. Install the underhood junction block bracket nuts (1,2).
Tighten the nuts to 10 N.m (88 lb in).
8. Install the underhood junction block bracket bolt (3).
Tighten the bolt to 25 N.m (18 lb ft).