saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Three-Way Catalytic Converter Damage Notice|Page 7129 > < Three-Way Catalytic Converter Damage Notice|Page 7127
Page 5
background image

7. If reinstalling the old HO2S, coat the threads with anti-seize compound, Saturn P/N 21485279 or equivalent.
8. Install the HO2S.

Tighten the sensor to 42 N.m (31 lb ft). 

9. Route the HO2S lead (1) through the heat shield trough (2), once done bend the trough until the HO2S lead is secured.