ION L4-2.4L (2007)
Valve Body: Service and Repair
Control Valve Body Replacement
Removal Procedure
1. Remove the transmission side cover.
2. Remove the bolts (9, 12 and 16) from the control valve body assembly (18).
3. Remove the control valve body assembly (18).
4. Remove and discard the valve body to spacer plate gasket (22).
Installation Procedure
1. Install the control valve body to spacer plate gasket (22) onto the spacer plate (23).
2. Install the control valve body assembly (18) onto the gasket (22).