Page 5
background image

4. Slide guide assembly forward and align each guide assembly with zero position. Zero position is aligned when hash marks on guide assembly are

aligned with front pin enclip on cable assembly guide.

5. Prior to motor installation, verify motor is in zero position by lining up the slot on outside of ring with the slot on the inside ring as shown. Cycle

motor with switch (or manually operate with small screwdriver in slot) until these slots line up.

6. Install motor and screws.