6. Remove surge tank from mounting tabs by rotating forward and inward.

7. Disconnect low coolant level sensor electrical connector.
8. Remove surge tank from vehicle.

INSTALLATION 

1. Connect low coolant level sensor electrical connector to surge tank.
2. Slide surge tank onto lower and rail mounting tabs.

3. Install surge tank rear retaining clip.