L200 L4-2.2L VIN F (2002)
Control Assembly: Service and Repair
Blower Motor Switch
REMOVAL
1. Remove control head.
2. Remove face plate.
3. Remove fan switch lever by prying straight off with a small flat blade screwdriver.
4. Using a flat blade screwdriver lift retaining barb on top of switch assembly and pull switch out of control head.
INSTALLATION