13. Connect negative battery cable.

Torque:
Battery Terminal Bolts: 17 N.m (13 ft-lbs)

IMPORTANT:  Vehicle must be level when filling cooling system.

14. Slowly add a mixture of 50/50 DEX-COOL(R) antifreeze and clean water to coolant surge tank until the level reaches Cold indicator (Surge tank

seam).

Cooling system volumes, including heater core
L81: 7.4 L (7.8 qt.)
L61: 7.0 L (7.4 qt.)

15. Start engine and check for cooling system leaks.
16. Run engine until thermostat has opened, use Tech 2 to verify ECT is 87°C (188°F) or greater. Add coolant as necessary to bring level up to

coolant surge tank Cold line.

17. Install coolant surge tank coolant cap.

High Pressure Safety Valve HVAC > < HVAC Module - Automatic Climate Control - Component Locations|Page 7846