saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Suction Pipe|Page 7869 > < Suction Pipe|Page 7867
Page 1
background image

Hose/Line HVAC: Service and Repair
Suction/Liquid Line Assembly

REMOVAL

1. Disconnect negative battery cable.

IMPORTANT:  Verifying the purity of the refrigerant with a purity identifier before recovery is recommended.

2. Recover refrigerant using an approved refrigerant recovery system. Measure the amount of oil removed during recovery and record.
3. Remove air box from rail.

4. Remove suction/liquid line assembly clamp fastener at engine mount area.

Suction Pipe|Page 7869 > < Suction Pipe|Page 7867