saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Suction Pipe|Page 1716 > < Suction Pipe|Page 1714
Page 3
background image

1. Install discharge hose, condenser end of line first, flexing hose to clear cradle brace.

NOTE:  Do not lubricate seal washers.

IMPORTANT:  Always install new seal washers to prevent refrigerant leaks.

2. Remove discharge line cap and install new seal washer.
3. Remove condenser block cap and install discharge line.
4. Hand start discharge line to condenser block bolt.

Torque:
Discharge Line-to-Condenser Block Bolt: 20 N.m (15 ft-lbs)

5. Remove cap from compressor discharge port.

NOTE:  Do not lubricate seal washers.

IMPORTANT:  Always install new seal washers to prevent refrigerant leaks.

6. Remove cap from discharge line and install new seal washer.
7. Install discharge line-to-compressor and hand start.

Torque:
Discharge Line-to-Compressor Bolt: 16 N.m (142 in-lbs)

8. Snap electrical harness clip onto discharge pipe.

9. Install discharge line clamp to cradle screw.

Torque:
Discharge Line Clamp Fastener-to-Cradle: 5 N.m (44 in-lbs)

Suction Pipe|Page 1716 > < Suction Pipe|Page 1714