saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Campaign - Deactivation Of Analog OnStar(R)|Page 32 > < Campaign - Deactivation Of Analog OnStar(R)|Page 30
Page 21
background image

Important:

Secure the wiring harness so that there is no risk of chafing and rattling.

9.4.

Fold back the wiring harness and tape over the connectors (C). Fold back the wiring harness once more and secure with cable ties (D).

9.5.

Install the right-hand rear luggage compartment in accordance with WIS - 8. Body - Interior equipment - Adjustment/Replacement.

10.

Install the ground cable to the battery's negative terminal.

11.

Clear the diagnostic trouble codes.

12.

Set the date and time, see WIS - 3. Electrical system - Information display (SID_ - Technical description.

2003-2005 Saab 9-3 (9400) 4D/5D; 2004-2005 Saab 9-3 (9400) CV

2003-2005 Saab 9-3 (9440) 4D/5D; 2004-2005 Saab 9-3 (9440) CV

Notice:

Handle the fiber optic cables with care or the signal may be distorted.

^

It is very important that the two leads in the connector are not confused with one another.

^

Do not splice the cables.

^

Do not bend the cable in a radius smaller than 25 mm (1 in).

^

Do not expose the cable to temperatures exceeding 185°F (85°C).

^

Keep the cable ends free from dirt and grime.

^

Do not expose the cable to impact as this may cause the transparent plastic to whiten, thereby reducing the intensity of the light and causing
possible communication interruptions.

^

The cable should not lie against any sharp edges as this may cause increased signal attenuation.

1.

Remove the ECU CU with a Tech 2(R) according to the following: Fault diagnosis - Select model year - Select Saab 9-3 Sport (9440) - All -
Add/Remove - Control Module - CU/PU - Remove.

2.

Remove the ground cable from the battery's negative terminal.

3.

Remove the floor console in accordance with WIS - 8. Body - Interior equipment - Adjustment/Replacement.

4.

Pry out the signal line from the SRS control module to the OnStar(R) control module and secure it:

Campaign - Deactivation Of Analog OnStar(R)|Page 32 > < Campaign - Deactivation Of Analog OnStar(R)|Page 30