6. Select a paved outdoor location to perform deployment. Clear a space on the floor and make certain no loose objects or flammable material are

within 4.6m (15 ft.) of the inflator module. Make sure you have sufficient ventilation.

7. When deploying a driver inflator module, place the inflator module in the center of the space with the vinyl trim cover facing up.

8. When deploying a passenger inflator module, refer to the following instructions:

^

Place the SIR Deployment Fixture SA9413NE in the center of the cleared area.

^

Fill plastic reservoir in deployment fixture with water or sand to provide sufficient stabilization of fixture during deployment.

^

Attach passenger inflator module in the deployment fixture using the Flange/Arm Mounting Method shown in illustration.

^

SECURITY HAND-TIGHTEN ALL FASTENERS PRIOR TO DEPLOYMENT

9. When deploying a curtain inflator impact module-front, refer to the following instructions:

^

Place the SIR Deployment Fixture SA9413NE in the center of the cleared area.

^

Fill plastic reservoir in deployment fixture with water or sand to provide sufficient stabilization of fixture during deployment.

^

Attach curtain inflator module in the deployment fixture using the Flange/Arm Mounting Method shown in illustration.

^

SECURELY HAND-TIGHTEN ALL FASTENERS PRIOR TO DEPLOYMENT