saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Diagrams|Page 866 > < Refrigerant Pressure Sensor / Switch, HVAC|Diagrams
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation

A/C PRESSURE SENSOR

A/C Pressure Sensor

The Air Conditioning (A/C) pressure sensor is located in the A/C high side pressure refrigerant line in front of the air box. The pressure sensor is a
transducer that varies resistance according to changes in high side refrigerant pressure. The PCM measures the signal voltage from the A/C pressure
sensor, which is a reduced value of the PCM 5-volt reference. The maximum voltage ranges of the sensor are around 0.1 volts at 0 psi to 4.9 volts at 459
psi
. The sensor input is used primarily by the PCM to determine when and what speed to turn the cooling fans On. It is also used to turn Off the A/C
relay if the system pressure is not within 180 - 2999 kPa (26-435) psi. The sensor input also aids in determining Idle Air Control (IAC) position for idle
speed during A/C operation.

Refrigerant Pressure Sensor / Switch, HVAC|Diagrams|Page 866 > < Refrigerant Pressure Sensor / Switch, HVAC|Diagrams