4. Re-assemble the cable.

^

Rewrap the conductors with the mylar tape. Use caution not to wrap the drain in the tape (1).

^

Follow the splicing instructions for copper wire and splice the drain wire.

IMPORTANT: Apply the mylar tape with the aluminum side inward. This ensures good electrical contact with the drain wire.

^

Wrap the drain wire around the conductors and tape with mylar tape.

5. Tape over the entire cable. Use a winding motion when you apply the tape.