saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Trunk Entrapment Prevention - Kit Installation|Page 11741 > < Trunk Entrapment Prevention - Kit Installation|Page 11739
Page 5
background image

15.

Connect cable conduit to release handle housing.

16. If not already connected, connect release handle wiring harness (included in kit) to release handle.

IMPORTANT

Due to stiffness of cable conduit, it may be necessary to pre-bend cable conduit prior to handle installation.

17. Align handle to decklid sheet metal as shown.

18. Using the release handle as a template, mark one hole location on decklid sheet metal.

NOTICE

If drill bit is allowed to drill into sheet metal at a depth greater than 6.5 mm (1/4 in.), outer surface of exterior panel may be penetrated.