L300 V6-3.0L VIN R (2001)
12. Remove inlet and outlet hose to heater water pump clamps and remove hoses.
INSTALLATION
IMPORTANT:
^
Heater inlet hose quick connect coupling collar is black. Heater outlet quick disconnect coupling collar is white.
^
White line on hoses should always be installed at 12 o'clock position. Install heater hose/heater water pump assembly into manifold clamp but do
not lock clamp.
1. Install block bolt to heater water pump mount and heat shield.
Torque: Water Pump Mount and Heat Shield Block Bolt: 8 Nm (71 inch lbs.)
2. Install heater water pump electrical connector.