saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Head Degas Hose|Page 3250 > < Head Degas Hose|Page 3248
Page 4
background image

12. Remove inlet and outlet hose to heater water pump clamps and remove hoses.

INSTALLATION 

IMPORTANT: 
^

Heater inlet hose quick connect coupling collar is black. Heater outlet quick disconnect coupling collar is white.

^

White line on hoses should always be installed at 12 o'clock position. Install heater hose/heater water pump assembly into manifold clamp but do
not lock clamp.

1. Install block bolt to heater water pump mount and heat shield.

Torque: Water Pump Mount and Heat Shield Block Bolt: 8 Nm (71 inch lbs.) 

2. Install heater water pump electrical connector.

Head Degas Hose|Page 3250 > < Head Degas Hose|Page 3248