Oil Filter Cap: 15 Nm (11 ft. lbs.) 

5. Install front exhaust manifold pipe assembly and gaskets.

NOTICE:  Do not tighten fasteners.

6. Install front exhaust manifold pipe to rear exhaust manifold pipe bolts.

7. Install front exhaust manifold pipe to exhaust manifold nuts.

Torque:
Exhaust Manifold Pipe-to-Exhaust Manifold Nuts: 30 Nm (25 ft. lbs.) 

8. Tighten front exhaust manifold pipe to rear exhaust manifold pipe bolts.

Torque:
Exhaust Manifold Pipe Bolts: 20 Nm (15 ft. lbs.) 

NOTICE:  Always use a nickel-based anti-seize compound Saturn P/N 21485279 (or equivalent) on the threads of the oxygen sensor. If the oxygen
sensor is replaced, do not apply anti-seize to the new sensor. New sensors have anti-seize pre-applied. Never use silicon product; silicon products will
cause damage to oxygen sensor.

Exhaust Manifold Replacement - Front|Page 3548 > < Exhaust Manifold Replacement - Front|Page 3546