10. Install oxygen sensor using O2 sensor wrench J39194C.

Torque:
Oxygen Sensors (Exhaust Manifold): 50 Nm (37 ft. lbs.) 

11. Connect rear exhaust manifold pipe oxygen sensor electrical connections.

12. Install exhaust manifold pipe heat shield.

Torque:
Exhaust Manifold Pipe Heat Shield Bolts: 8 Nm (71 inch lbs.) 

13. Start vehicle and inspect for exhaust leaks.