saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

A/C - Unpleasant Odors on Vehicle Start Up|Page 9774 > < A/C - Unpleasant Odors on Vehicle Start Up|Page 9772
Page 8
background image

Tighten the Evaporator Core Service Door-to-HVAC Module Fasteners to 1 N.m (9 in-lbs).

25.

Install right side heater duct assembly and retainer.

26.

Install insulator support to front-of-dash studs by sliding forward.

27.

Install right side I/P lower dash insulator and retainers.

Important:

Step 27 should be skipped if vehicle does not have the I/P lower dash insulator.

28.

Install right side console extension.

29.

Allow evaporator core to soak for 15 minutes.

30.

Dry evaporator:

30.1. Adjust HVAC controls to hottest temperature setting.

^

For models with manual HVAC (RPO C60), adjust temperature to full hot (highest setting). Set mode to heater only, turn RECIRC on,
and make sure A/C button is off.

^

For models with automatic climate control (RPO C68), adjust temperature to 32°C (90°F) in AUTO mode.

30.2. Set fan control to highest setting (for models with manual HVAC, RPO C60), or AUTO (for models with automatic climate control, RPO

C68).

30.3. Close doors and open windows 12.7 mm (0.5 in).

30.4. Start engine and allow to reach operating temperature.

30.5. When engine reaches operating temperature, allow blower motor to operate on HI blower for 5 minutes.

31.

Properly dispose of cooling coil coating runoff collected in drain pan into approved container.

A/C - Unpleasant Odors on Vehicle Start Up|Page 9774 > < A/C - Unpleasant Odors on Vehicle Start Up|Page 9772