saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

All Technical Service Bulletins for Evaporator Case:|01-T-27 > < A/C - Unpleasant Odors on Vehicle Start Up|Page 9782
Page 18
background image

8.

Cut the terminal end off circuit 268 and discard.

9.

Locate circuit 502, in cavity A11 (red 3.0 mm wire), in the gray 68-way IP connector.

10.

Cut circuit 502 about 51 mm (2 in.) from the connector.

11.

For information on splicing wires, refer to "wiring Splicing" instructions in this bulletin.

Using the 3-wire splice connector (P/N 22709318), splice the three cut ends of circuits 268 and 502 to the three wires in the connector, using the
yellow splice sleeves.

Important:

For step 11 refer to electrical schematic.

12.

Reinstall the gray 68-way IP connector to the LIPFB.

13.

Using a tie strap, secure the splice connector to the IP harness out of the way of the LIPFB.

14.

Reinstall the LIPFB to the mounting studs (1 forward, 1 rearward).

15.

Install nuts.

16.

Install lower left garnish molding.

17.

Enable SIR system. Refer to "SIR Disable/Enable" procedure in the appropriate model year Saturn L-Series Restraints Service Manual.

18.

Connect negative battery cable.

Tighten

Tighten the Battery Terminal Bolts to 17 N.m (13 ft-lbs).

19.

Set radio station presets.