Expansion Valve: Service and Repair

THERMAL EXPANSION VALVE (TXV)

REMOVAL

IMPORTANT:  Verifying the purity of the refrigerant with a purity identifier before recovery is recommended.

1. Recover refrigerant using an approved refrigerant recovery system. Measure the amount of oil lost during recovery and record.

CAUTION:  DO NOT REMOVE HOSES OR LINES BEFORE SYSTEM IS FULLY DISCHARGED.

NOTE:  When removing the TXV, keep dirt and foreign material from getting on or into the O-ring sealing surfaces. Clean tools and a clean work
area are important for proper service. The TXV seal area should be cleaned before any repairs are performed. The parts must be kept clean at all times
and any parts to be assembled should be cleaned with a non-petroleum based solvent and dried with air. Use only lint free cloths to wipe parts. Do not
allow solvent to enter evaporator or hoses.

IMPORTANT:  On earlier vehicles a bolt was used instead of a stud/nut.

2. Remove suction/liquid line block-to-TXV retaining nut.
3. Remove suction/liquid line block from TXV by gently rocking while pulling forward.
4. Install cap on suction/liquid line assembly to prevent oil spillage.

5. Remove TXV retaining bolts