22. Install blower motor resistor card.

Torque:
Blower Motor Resistor Card Fastener: 1.0 N.m (9 in-lbs)

23. Install temperature door cable eyelet over temperature door lever. Do not install housing into retaining clip at this time.

24. Attach electrical harness to back of module. Connect actuators, blower resistor, and route to blower motor.
25. Push blower motor harness grommet through hole then pull back to seat.
26. Install harness to case screw at mode actuator.