saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Refrigerant|Service and Repair > < General Description|Page 10112
Page 1
background image

Refrigerant: Testing and Inspection
Electronic Leak Testers

For restricted access areas (such as sections of evaporator and condenser) an electronic leak detector is advisable.

CAUTION:  CARE SHOULD BE TAKEN TO PREVENT PERSONAL INJURY WHICH COULD OCCUR DUE TO TOUCHING A HOT
ENGINE WHEN TESTING. TESTS SHOULD BE DONE WITH THE ENGINE OFF AND AS COOL AS POSSIBLE. DO NOT OPERATE
THE DETECTOR IN A COMBUSTIBLE ATMOSPHERE SINCE ITS SENSOR OPERATES AT A HIGH TEMPERATURE.

The successful use of this and any other electronic leak detector depends greatly upon the scan rate and upon carefully following manufacturer's
instructions regarding calibration, operation, and maintenance. Each joint must be completely circled moving at 25-50 mm (1-2 in.) inches per second
with tip of probe as close to surface as possible but no more than a 6.35 mm (1/4 in.) away and without blocking air intake. A leak is indicated when the
audible tone goes from a steady one to two clicks per second to a solid alarm. The balance knob should be adjusted frequently to maintain the one to two
clicks per second rate.

Refrigerant|Service and Repair > < General Description|Page 10112