L300 V6-3.0L VIN R (2001)
8. Install heater core inlet quick connect to heater inlet pipe (closest to driver's side). Holding quick connect by black collar, slide onto heater core
pipe. When quick connect engages heater core pipe bead, collar will slide towards front of dash and lock into position. A green paint band will be
visable when collar is properly positioned.
9. Verify proper engagement of quick connect by attempting to pull hose off of heater pipe.
10. Install heater core outlet quick connect to heater outlet pipe (closest to passenger's side). Holding quick connect by white collar, slide onto heater
core pipe. When quick connect engages heater core pipe bead, collar will slide towards front of dash and lock into position. A green paint band
will be visable when collar is properly positioned.
11. Verify proper engagement of quick connect by attempting to pull hose off of heater pipe.
12. With hoses properly positioned, close heater hose assembly to manifold clamp.
13. Connect negative battery cable.
Torque:
Battery Terminal Bolts: 17 Nm (13 ft. lbs.)
14. Fill cooling system.
15. Use fresh water to rinse away any coolant that was spilled during service.