23. Install the pusher fan harness into mounting tabs on puller fan shroud.
24. Connect pusher fan electrical connector.
25. Connect negative battery cable.

Torque: 17 N.m (151 in-lbs)

26. Evacuate, charge, and leak check the A/C system.