saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

A/C - Odor From Outlets at Vehicle Start Up|Page 11413 > < A/C - Odor From Outlets at Vehicle Start Up|Page 11411
Page 14
background image

17.3 Splice GRN/WHT (L61) or BLK/WHT (L81) wire from UHFB 68-way connector and WHT wire from delayed blower control module onto

terminal end PN # 12034046.5 mm to .8 mm (20 to 18 gage).

17.4 Place terminal end back into UHFB 68-way connector at terminal C4 (L61) or A7 (L81).

17.5 Connect 68-way connector to UHFB.

18.

Open Engine harness conduit from UHFB to bulkhead.

19.

Route WHT wire from delayed blower motor along this harness, placing the wire inside the conduit.

20.

Using electrical tape spot tape the engine harness.

21.

Close UHFB.

22.

Reinstall coolant reservoir line.

23.

Reinstall battery shield.

A/C - Odor From Outlets at Vehicle Start Up|Page 11413 > < A/C - Odor From Outlets at Vehicle Start Up|Page 11411