Refrigerant: Testing and Inspection
Refrigerant/Oil Overcharge

Refrigerant/Oil Overcharge

KEY:

HIGH PRESSURE SWITCH CYCLES COMPRESSOR ON AND OFF AT HIGH AMBIENT AIR TEMPERATURES.

THEN: System may be operating in an overcharged condition.

^

An overcharged condition will generate a poor and/or intermittent cooling complaint at higher ambient air temperatures. Intermittent
complaints are caused by the pressure switch cycling the compressor On and Off.

^

Reclaim system using an approved recovery system, evacuate and recharge with 0.85 kg (1.875 lbs.) of R-134a refrigerant.

^

Run another performance test.

^

An oil overcharge can occur if a compressor change is made without proper oil balancing. Review vehicle service history for compressor
service.