saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Coolant Outlet|Service and Repair|Page 3629 > < Head Degas Hose|Page 3625
Page 1
background image

Coolant Outlet: Service and Repair

REMOVAL 

1. Disconnect negative battery cable.
2. Drain coolant.
3. Position approved coolant container under vehicle below heater hose connections to catch any coolant that may be trapped in heater hoses.

4. Open heater hose assembly to manifold clamp.

IMPORTANT:  Green plastic rings may be found hanging on heater pipe 5 after hose removal, these are a manufacturing aids and should be
discarded.

5. Remove heater core inlet hose from heater core pipe by depressing quick connect collar tab, located at 6 o'clock, and pulling black collar towards

front of vehicle and then pulling quick connect off of heater core pipe.

Coolant Outlet|Service and Repair|Page 3629 > < Head Degas Hose|Page 3625