4. Remove front transaxle mount through bolt.
5. Raise powertrain with engine support fixture to provide clearance to pull extension housing above coolant module.
6. Remove oil level indicator tube and coolant extension tube bolt.
7. Remove oil level indicator tube by pulling upwards.
INSTALLATION
1. Install two new O-rings onto coolant extension housing.
2. Lubricate O-ring with coolant and install extension housing.
3. Install oil level indicator tube and coolant extension housing bolt.
-
Torque: 20 Nm (15 ft. lbs.)